Product Description
CHEMI-PROOF Paint is a technologically advanced, unique, Chemical resistant air drying coating system
Features
- Protects the surface from all type of chemicals including Acids & Alkalis
- Resists corrosion from all types of Acids & Alkalis
- Temperature Resistance upto 300 deg Celcius(570 deg F)
- Offers protection in a single coat
- Simple method of application
Recommended for corrosion protection for
- Chemical treatment plants
- Acid/Alkali storage plants, Tanks, Pipelines etc
- Acid/Alkali treatment plants
- Industries where Acids, Alkalis or Chemicals are used for various processes
Technical Data
Colour |
: |
Available in limited colors |
Coverage |
: |
10 to 15 m2 per Litre. |
Coating Thickness |
: |
50 + 5 microns DFT |
Method of Application |
: |
Brush, Air Spray, Airless Spray, Dipping, Flow Coating, Curtain coating, Tumbling etc. |
Film Properties
Drying Time ( air dry ) |
: |
Touch Dry 60 minutes
Hard Dry 6 hours
|
Over coating interval with self |
: |
24 Hours |
Finish |
: |
Glossy and smooth |
Water Resistance (7 Days) |
: |
Excellent |
Salt Water Resistance (7 Days) |
: |
Excellent |
Acid Resistance |
: |
Excellent |
Dilute HCl (7 Days) |
: |
Excellent |
Dilute HNO3 (7 Days) |
: |
Excellent |
Dilute H2SO4 (7 Days) |
: |
Excellent |
Conc. HCl (24 Hours) |
: |
Excellent |
Alkali Resistance |
: |
Excellent |
Dilute NaOH (7 Days) |
: |
Excellent |
Dilute KOH (7 Days) |
: |
Excellent |
Dilute Na2CO3 (7 Days) |
: |
Excellent |
Conc. NaOH (24 Hours) |
: |
Excellent |
Adhesion ( by cross hatch method ) |
: |
100% |
Flexibility |
: |
Passes O T bend test |
Scratch Hardness |
: |
1000 gms. |
Impact Resistance |
: |
more than 60 Kg cm. |
Weather Resistance |
: |
more than 2 years |
Salt Spray Test (1000 hours) |
: |
Passes the test |
U/V resistance |
: |
Excellent |
Humidity Resistance (7 Days) |
: |
Excellent |
Temperature Resistance |
: |
Upto 300 0C ( 5700F ) |
Application Procedure and Other Details
Mixing |
: |
Shake well the container before use |
Method of Application |
: |
The paint can be applied by any method e.g. brush, Air spray, Airless Spray, Roller, Dipping Flow coating, Curtain coating, Tumbling etc. |
Film Thickness |
: |
The wet film thickness ( WFT ) should not be less than 100 microns. |
Thinner |
: |
Use G-Tech Thinner for thinning the paint. Do not thin more than required. |
Surface Preparation
- All surfaces to be coated must be perfectly cleaned. The presence of oil grease, dust, rust, etc. on the surface will not give satisfactory result.
- Oil grease should be removed by either wipe out method or solvent/emulsion degreasing method
- Rust, scales and other deposites on the metal surface should be cleaned by abrasive blast cleaning method or by using wire brushes or abrasion tools.
- DO NOT APPLY ANY TYPE OF PRIMER OR SEALER ON THE SURFACE
- The paint should be applied directly on the surface. It can be recoated any number of times to increase the film thickness.
|